300kW Weifang Diesel Generator Set diesel generator set
300kW Weifang Diesel Generator Set diesel generator set
300kW Weifang Diesel Generator Set diesel generator set
300kW Weifang Diesel Generator Set diesel generator set
300kW Weifang Diesel Generator Set diesel generator set
300kW Weifang Diesel Generator Set diesel generator set
300kW Weifang Diesel Generator Set diesel generator set
300kW Weifang Diesel Generator Set diesel generator set

Weifang 300kW Diesel Generator

The 300kW generator set powered by Weifang 6126IZLD engine is designed for high-demand industrial applications. It offers excellent load performance and durability.

Share:

  • Details Introduction
  • FAQ

300kW Weifang Diesel Generator is supplied by Probe Power for buyers who need reliable generator, engine or power-equipment support with clear configuration, replacement and export communication. 300kW Weifang diesel generator set for industrial standby, commercial backup and project power applications.

Description

The 300kW generator set powered by Weifang 6126IZLD engine is designed for high-demand industrial applications. It offers excellent load performance and durability.


Key Features

  • High Capacity: High load capacity for heavy equipment.
  • Continuous Power: Stable performance under continuous operation.
  • Efficiency: Fuel-efficient for mid-to-large power range.
  • Versatility: Suitable for prime and standby use.

Technical Specifications

Generator Set

ParameterSpecification
ModelPRF300GF
Power300 kW / 375 kVA
Current540 A
Dimensions3000×1200×1800mm
Weight3000kg

Engine

ParameterSpecification
BrandWeifang
Model6126IZLD
Prime Power338 kW
Standby Power358 kW
Fuel Consumption208 g/kWh
Speed1500/1800 rpm
CoolingWater-cooled

Alternator

ParameterSpecification
BrandPROBE (100% copper brushless alternator)
Optional BrandsStamford / Leroy Somer / Marathon
TypeBrushless self-excited
ProtectionIP22 / IP23

Applications

  • Production: Industrial production lines.
  • Mining: Mining operations.
  • Water Systems: Pump stations.
  • Infrastructure: Infrastructure projects.

Optional Configurations

  • Soundproof canopy
  • Trailer-mounted generator
  • Rain canopy
  • Automatic control panel (ATS / remote monitoring)

Why Choose Us

  • Flexible customization based on project requirements
  • Stable supply chain and fast delivery
  • Full lifecycle technical support
  • Competitive pricing with high reliability
  • Q
    What are the continuous fuel consumption benchmarks, cooling heat rejection, and ambient derating thresholds of this 300kW (375 kVA) Weifang generator set?
    A

    The 300kW / 375 kVA generator unit is engineered for continuous Prime Power (PRP) duties with an emergency standby rating (ESP) of 330kW / 412.5 kVA at a 0.8 lagging power factor. Driven by a heavy-displacement Weifang multi-cylinder turbocharged and charge-air intercooled diesel engine operating at 1500 RPM (50Hz) or 1800 RPM (60Hz), brake-specific fuel consumption (BSFC) averages between 208 and 218 g/kW·h. Under steady-state industrial loading, actual hourly fuel burn rates measure approximately 39.5 L/h at 50% load, 56.8 L/h at 75% load, and 74.5 L/h at 100% continuous prime output. The cooling circuit rejects approximately 210–230 kW of thermal energy through the jacket water and intercooler circuits. Standard configurations maintain full rated prime output without thermal derating in ambient temperatures up to 40°C and altitudes up to 1,000 meters above sea level (ASL); above these operational baselines, derating parameters follow standard engineering curves of 1% per 100 meters elevation and 2% per 5°C ambient temperature rise.

  • Q
    What circuit breaker switchgear specifications, cable connection provisions, and acoustic enclosure engineering are featured on the 300kW Weifang platform?
    A

    Operating at 400V/230V 3-phase line distribution, the 300kW unit generates a continuous full-load line current of approximately 541 Amperes (surging up to 595 Amperes during standby duty). Electrical protection is provided by a factory-mounted 630A or 800A 3-pole/4-pole electronic-trip Molded Case Circuit Breaker (MCCB) with adjustable long-time pickup (Ir = 0.4–1.0 × In) and short-time delay (Isd) settings for selective tripping coordination with facility distribution boards. The terminal cubicle features extended tinned copper busbar spreaders and pre-punched removable gland plates configured to accommodate dual parallel heavy conductor runs (e.g., 2 × 240 mm² or 2 × 300 mm² copper cables per phase) alongside a dedicated solid neutral link. The weatherproof soundproof canopy is engineered from CNC-formed 2.0mm steel incorporating dual-chamber intake/exhaust sound-attenuating splitters and an internally insulated residential muffler, damping operational noise to 72–74 dB(A) at 7 meters. Control instrumentation utilizes a Deep Sea DSE7320 MKII or SmartGen HGM7220 controller supporting RS485 Modbus RTU telemetry for building management system (BMS) integration and automated ATS transfer.

For more information, please contact us.

Our professional team can provide scientific configuration recommendations and one-stop integration services based on your installation environment, operating mode, compliance requirements, and budget, ensuring optimal performance and lifecycle value.

Request online

For more information, please contact us
Free to contact us